  • 품질이 좋지 않은 제품이 관리됨(Poor quality product administered)
  • 제품 온도 편차 문제(Product temperature excursion issue)

이환 중 질병

지병

기타 의료

이전 예방접종

알레르기

임상 검사

증상 상세

Vaccine administered after more than 1 temperature excursion; Vaccine administered after more than 1 temperature excursion; This spontaneous case was reported by an other health care professional and describes the occurrence of PRODUCT TEMPERATURE EXCURSION ISSUE (Vaccine administered after more than 1 temperature excursion) and POOR QUALITY PRODUCT ADMINISTERED (Vaccine administered after more than 1 temperature excursion) in a 59-year-old female patient who received mRNA-1273 (Moderna COVID-19 Vaccine) (batch nos.
019B21A and 014M20A) for COVID-19 vaccination.
No Medical History information was reported.
On 28-Feb-2021 at 9:54 AM, the patient received dose of mRNA-1273 (Moderna COVID-19 Vaccine) (unknown route) .
5 milliliter.
On 28-Mar-2021 at 10:12 AM, received dose of mRNA-1273 (Moderna COVID-19 Vaccine) (unknown route) dosage was changed to .
5 milliliter.
On an unknown date, the patient experienced PRODUCT TEMPERATURE EXCURSION ISSUE (Vaccine administered after more than 1 temperature excursion) and POOR QUALITY PRODUCT ADMINISTERED (Vaccine administered after more than 1 temperature excursion).
At the time of the report, PRODUCT TEMPERATURE EXCURSION ISSUE (Vaccine administered after more than 1 temperature excursion) and POOR QUALITY PRODUCT ADMINISTERED (Vaccine administered after more than 1 temperature excursion) outcome was unknown.
For mRNA-1273 (Moderna COVID-19 Vaccine) (Unknown), the reporter did not provide any causality assessments.
The age of patient was provided as 59.
47 for dose administered on 28-Mar-2021 and 59.
39 for dose administered on 28-Feb-2021 Concomitant products were not provided.
On 28-Feb-2021, Excursion time was 09 AM, temperature was 27 and 01 PM temperature was 26, total doses given for the day was 152, condition of vaccine prior to administration was not frozen, vaccine was moved to fridge on 24-Feb-2021, vial was moved to clinic on 27-Feb-2021.
20 vials were sent to clinic.
Vaccine BUD date was 26-Mar-2021.
On 28-Feb-2021, vials were stored in cooler 1, at following time and temperature respectively, 9 AM: 27, 10 AM: 40, 11 AM: 44, 12 PM: 46, 1PM: 26, 2 PM: 37, 3 PM: 43 and 4 PM: 45.
On 28-Mar-2021, Excursion time was 10 AM, temperature was 35, total doses given for the day was 150, condition of vaccine prior to administration was not frozen, vaccine was moved to fridge on 23-Mar-2021, vial was moved to clinic on 27-Mar-2021.
15 vials were sent to clinic.
Vaccine BUD date was 22-Apr-2021.
On 28-Mar-2021, vials were stored in cooler 1, at following time and temperature respectively 8 AM: 43, 9 AM: 38, 10 AM: 35, 11 AM: 44, 12 PM: 44, 1PM: 41, 2 PM: 46, 3 PM: 46, 4 PM: 42, and 5 PM: 41.
The vials were only punctured right before administration and all doses were drawn from the vial due to high-pace clinic.
Temperature recordings were taken using a Fisher brand traceable temperature monitor at every hour.
After administration, the vial was returned to the freezer/refrigerator, or maintained at room temperature.
It was reported that the patient was administered with vaccines that experienced more than 1 temperature excursion during 33 weeks in 2021.
The HCP explained that each time a vial was put into a cooler, there was a period of 1 hour or 1 and half hour approximately, when the temperature data logger registered 34 or 35 degree F.
Treatment medications were not reported.
This case was linked to MOD-2022-566976 (Patient Link).